Traditional T-Series - Roof Models

• Extract/intake model in 4 sizes: 6”, 7”, 9” and 12”
• Patented electronic shutter system ensures quiet, trouble free operation
• For the very best from your fan use the Ecotronic controller
• T-Series controllers and sensors save energy by only switching on the units when you want them to, either manually
or automatically
• Easy fit connector Top Socket, standard on all models

Select a product

UK’s No. 1 Commercial Fan
With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. All four sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.

T-Series features a unique speed control pack which enables high, medium or low speed to be preset to suit room size or required duty. When used with a T-Series TSC controller, the speed control pack is removed from the T-Series ventilating unit and fitted into the 3-pin socket in the back of the controller. The Vent-Axia Ecotronic controller gives even greater running economy with its minimum speed setting and 'E' mode. When using the Ecotronic controller the speed control pack remains in the fan.

Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools.

PRODUCT SPECIFICATION:

Shutter
With energy saving in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It will operate on both intake and extract and at any angle of mounting.
The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection.
When the ventilating unit is used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.
TL models do not have a shutter. They are suitable for systems where no shutter is required or in a ducted system where the shutter is located elsewhere.
Electrical
Motor purpose-designed. Suitable for running at any angle. Quiet running, enclosed. Suitable for operation in ambient temperatures from -40°C to +50°C.
Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.). Supply voltage 220-240V/1/50 Hz (120V/1/60 Hz).
Top Socket
A connector Top Socket is now standard on all T-Series fans. Allowing fast and trouble-free mains connection.

PERFORMANCE:

Output is for the extract airflow on HIGH.

DIMENSIONS:

Size 6 (150mm) 7 (190mm) 9 (230mm) 12 (300mm)
A 100 136 136 171
B 130 130 150 177
C 226 265 304 381
D 220 258 302 378
E 54 54 54 54
F 285 400 400 500
Fixing hole dia. 184 222 260 337
Weight (kg) 3.96 4.89 6.22 9.28
Image of TX6RF
TX6RF
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Please call 0344 856 0590 for further availability information.
Image of TX7RF
TX7RF
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Please call 0344 856 0590 for further availability information.
Image of TX9RF
TX9RF
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Please call 0344 856 0590 for further availability information.
Image of TX12RF
TX12RF
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Please call 0344 856 0590 for further availability information.
Image of T-Series Controller
T-Series Controller
Three speeds. Choice of extract/intake Shutter open, fan Off setting Sensor mode. Enables external electro mechanical switches, eg: Ecotronic, HumidiSwitch, ThermoSwitch and TimeSwitch to control the fan.
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Controller
Ecotronic Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Please call 0344 856 0590 for further availability information.
Image of Ambient Response Humidity Sensor Lo-Carbon
Ambient Response Humidity Sensor Lo-Carbon
Designed specifically for the Lo-Carbon product range. The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Night time RH increment setback feature suppresses nuisance ripping when the humidity level gradually rises as the temperature falls. Features & Benefits: Ambient operating temp range +5°C to +40°C. Changeover relay switch. DEMKO Approved. Dimensions: 87 x 87 x 33mm (H x W x D). Operating range: 30%-90% RH. Pullcord override and neon indicator. Will fit single gang box for surface mounting. Downloads Catalogue Pages
Please call 0344 856 0590 for further availability information.
Image of Air Quality Sensor (Sentinel)
Air Quality Sensor (Sentinel)
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Humidity Sensor (Sentinel)
Ecotronic Humidity Sensor (Sentinel)
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
Please call 0344 856 0590 for further availability information.

Overview

UK’s No. 1 Commercial Fan
With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. All four sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.

T-Series features a unique speed control pack which enables high, medium or low speed to be preset to suit room size or required duty. When used with a T-Series TSC controller, the speed control pack is removed from the T-Series ventilating unit and fitted into the 3-pin socket in the back of the controller. The Vent-Axia Ecotronic controller gives even greater running economy with its minimum speed setting and 'E' mode. When using the Ecotronic controller the speed control pack remains in the fan.

Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools.

Technical

PRODUCT SPECIFICATION:

Shutter
With energy saving in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It will operate on both intake and extract and at any angle of mounting.
The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection.
When the ventilating unit is used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.
TL models do not have a shutter. They are suitable for systems where no shutter is required or in a ducted system where the shutter is located elsewhere.
Electrical
Motor purpose-designed. Suitable for running at any angle. Quiet running, enclosed. Suitable for operation in ambient temperatures from -40°C to +50°C.
Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.). Supply voltage 220-240V/1/50 Hz (120V/1/60 Hz).
Top Socket
A connector Top Socket is now standard on all T-Series fans. Allowing fast and trouble-free mains connection.

PERFORMANCE:

Output is for the extract airflow on HIGH.

DIMENSIONS:

Size 6 (150mm) 7 (190mm) 9 (230mm) 12 (300mm)
A 100 136 136 171
B 130 130 150 177
C 226 265 304 381
D 220 258 302 378
E 54 54 54 54
F 285 400 400 500
Fixing hole dia. 184 222 260 337
Weight (kg) 3.96 4.89 6.22 9.28

Models

Image of TX6RF
TX6RF
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Please call 0344 856 0590 for further availability information.
Image of TX7RF
TX7RF
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Please call 0344 856 0590 for further availability information.
Image of TX9RF
TX9RF
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Please call 0344 856 0590 for further availability information.
Image of TX12RF
TX12RF
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Please call 0344 856 0590 for further availability information.

Accessories

Image of T-Series Controller
T-Series Controller
Three speeds. Choice of extract/intake Shutter open, fan Off setting Sensor mode. Enables external electro mechanical switches, eg: Ecotronic, HumidiSwitch, ThermoSwitch and TimeSwitch to control the fan.
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Controller
Ecotronic Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Please call 0344 856 0590 for further availability information.
Image of Ambient Response Humidity Sensor Lo-Carbon
Ambient Response Humidity Sensor Lo-Carbon
Designed specifically for the Lo-Carbon product range. The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Night time RH increment setback feature suppresses nuisance ripping when the humidity level gradually rises as the temperature falls. Features & Benefits: Ambient operating temp range +5°C to +40°C. Changeover relay switch. DEMKO Approved. Dimensions: 87 x 87 x 33mm (H x W x D). Operating range: 30%-90% RH. Pullcord override and neon indicator. Will fit single gang box for surface mounting. Downloads Catalogue Pages
Please call 0344 856 0590 for further availability information.
Image of Air Quality Sensor (Sentinel)
Air Quality Sensor (Sentinel)
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Humidity Sensor (Sentinel)
Ecotronic Humidity Sensor (Sentinel)
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
Please call 0344 856 0590 for further availability information.

Downloads