Traditional Standard Range - Wall Model

• Extract/intake models in 4 sizes: 6", 7", 9" and 12"
• IPX4 Rated
• White fascia, wall sleeve and black external weather louvre
• Optional shutter available
• Manufactured in weather-resistant polymeric materials
• For the best performance from your fan, use an Ecotronic controller

Select a product

The proven Standard range wall models are designed to fit flush into most double brick walls using the rigid wall liner supplied with the unit. Provision is made within the liner for conduit entry. When installed, only the ivory fascia is visible on the internal wall face. The external weather louvre fits flush to the outside. A shutter is available as an accessory which can be easily fitted within the unit, see below.

On new building work the installation and wiring of the wall liner can be completed prior to the final installation of the unit and controller. Fully shrouded connectors on the fascia automatically connect the wiring to the motor when fitted to the wall liner.

Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools. The fascia, motor impeller assembly unplugs from the wall sleeve. The external weather louvre is removed into the room for cleaning. All plastic components can be washed.

PRODUCT SPECIFICATION:

Motor
The motor is purpose-designed. Suitable for running at any angle. Quiet running, enclosed, sealed for life ball bearings.
Supply voltage: 220-240V/1/50Hz.
Suitable for operation in ambient temperatures from -40°C to +40°C.
Fitted with Standard Thermal Overload Protection (S.T.O.P.).
Shutter
Type SD/R. This extract/intake shutter fits inside the Vent-Axia unit and closes against unwanted backdraughts. It can be fitted at the same time as the unit or at a later date if required. Airflow operated for extract use, cord operated lock for intake use.

DIMENSIONS:

Impeller dia. 150mm 190mm 230mm 300mm
A 279 279 279 279
B 203 279 279 356
C 279 362 362 448
Fixing hole Square 235 311 311 400
Weight 4.1kg 5.7kg 6.7kg 10.1kg
Image of Standard Range Wall Model S6WL
Standard Range Wall Model S6WL
Classic Retro-Styled Ventilation
Please call 0344 856 0590 for further availability information.
Image of Standard Range Wall Model S7WL
Standard Range Wall Model S7WL
Classic Retro-Styled Ventilation
Please call 0344 856 0590 for further availability information.
Image of Standard Range Wall Model S9WL
Standard Range Wall Model S9WL
Classic Retro-Styled Ventilation
Please call 0344 856 0590 for further availability information.
Image of Standard Range Wall Model S12WL
Standard Range Wall Model S12WL
Classic Retro-Styled Ventilation
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Controller
Ecotronic Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Please call 0344 856 0590 for further availability information.
Image of Ambient Response Humidity Sensor Lo-Carbon
Ambient Response Humidity Sensor Lo-Carbon
Designed specifically for the Lo-Carbon product range. The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Night time RH increment setback feature suppresses nuisance ripping when the humidity level gradually rises as the temperature falls. Features & Benefits: Ambient operating temp range +5°C to +40°C. Changeover relay switch. DEMKO Approved. Dimensions: 87 x 87 x 33mm (H x W x D). Operating range: 30%-90% RH. Pullcord override and neon indicator. Will fit single gang box for surface mounting. Downloads Catalogue Pages
Please call 0344 856 0590 for further availability information.
Image of Air Quality Sensor (Sentinel)
Air Quality Sensor (Sentinel)
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Humidity Sensor (Sentinel)
Ecotronic Humidity Sensor (Sentinel)
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
Please call 0344 856 0590 for further availability information.

 

Raadpleeg de tab Downloads voor technische informatie

 

 

Overview

The proven Standard range wall models are designed to fit flush into most double brick walls using the rigid wall liner supplied with the unit. Provision is made within the liner for conduit entry. When installed, only the ivory fascia is visible on the internal wall face. The external weather louvre fits flush to the outside. A shutter is available as an accessory which can be easily fitted within the unit, see below.

On new building work the installation and wiring of the wall liner can be completed prior to the final installation of the unit and controller. Fully shrouded connectors on the fascia automatically connect the wiring to the motor when fitted to the wall liner.

Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools. The fascia, motor impeller assembly unplugs from the wall sleeve. The external weather louvre is removed into the room for cleaning. All plastic components can be washed.

Technical

PRODUCT SPECIFICATION:

Motor
The motor is purpose-designed. Suitable for running at any angle. Quiet running, enclosed, sealed for life ball bearings.
Supply voltage: 220-240V/1/50Hz.
Suitable for operation in ambient temperatures from -40°C to +40°C.
Fitted with Standard Thermal Overload Protection (S.T.O.P.).
Shutter
Type SD/R. This extract/intake shutter fits inside the Vent-Axia unit and closes against unwanted backdraughts. It can be fitted at the same time as the unit or at a later date if required. Airflow operated for extract use, cord operated lock for intake use.

DIMENSIONS:

Impeller dia. 150mm 190mm 230mm 300mm
A 279 279 279 279
B 203 279 279 356
C 279 362 362 448
Fixing hole Square 235 311 311 400
Weight 4.1kg 5.7kg 6.7kg 10.1kg

Models

Image of Standard Range Wall Model S6WL
Standard Range Wall Model S6WL
Classic Retro-Styled Ventilation
Please call 0344 856 0590 for further availability information.
Image of Standard Range Wall Model S7WL
Standard Range Wall Model S7WL
Classic Retro-Styled Ventilation
Please call 0344 856 0590 for further availability information.
Image of Standard Range Wall Model S9WL
Standard Range Wall Model S9WL
Classic Retro-Styled Ventilation
Please call 0344 856 0590 for further availability information.
Image of Standard Range Wall Model S12WL
Standard Range Wall Model S12WL
Classic Retro-Styled Ventilation
Please call 0344 856 0590 for further availability information.

Accessories

Image of Ecotronic Controller
Ecotronic Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Please call 0344 856 0590 for further availability information.
Image of Ambient Response Humidity Sensor Lo-Carbon
Ambient Response Humidity Sensor Lo-Carbon
Designed specifically for the Lo-Carbon product range. The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Night time RH increment setback feature suppresses nuisance ripping when the humidity level gradually rises as the temperature falls. Features & Benefits: Ambient operating temp range +5°C to +40°C. Changeover relay switch. DEMKO Approved. Dimensions: 87 x 87 x 33mm (H x W x D). Operating range: 30%-90% RH. Pullcord override and neon indicator. Will fit single gang box for surface mounting. Downloads Catalogue Pages
Please call 0344 856 0590 for further availability information.
Image of Air Quality Sensor (Sentinel)
Air Quality Sensor (Sentinel)
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Humidity Sensor (Sentinel)
Ecotronic Humidity Sensor (Sentinel)
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
Please call 0344 856 0590 for further availability information.

Downloads