Traditional Standard Range - Roof Models

• Extract model in 4 sizes: 6", 7", 9" and 12"
• IPX4 Rated
• Colour: White
• Wide range of sensors available
• Manufactured in weather-resistant polymeric materials
• For the best performance from your fan, use an Ecotronic controller

Select a product

Classic Retro-Styled Ventilation
A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard range makes installation and routine cleaning easy.

Featuring a low profile cowl, the unit is ready for fitting into horizontal, angled and vertical glass, fixing plates on roofs and in vertical windows or walls in exposed areas. With Vent-Axia roof plate assemblies, all four sizes can be fitted easily into flat roofs. Suitable for roof installation plus window and wall installation in exposed areas (eg: coastal positions).

Vent-Axia's spigot and ring method of fixing ensures easy installation and weather proof joint. We recommend the use of sealing compound under the upper part of the unit when fitted in roofs.

Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools.

Motor
Purpose designed enclosed motor. Suitable for running at any angle. Quiet running, continuous rated motor with sealed for life ball bearings.

Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.).

Supply voltage 220-240V/1/50Hz.

All Standard Range roof models are designed to fit directly into horizontal and sloping windows including wired cast, up to 10mm thick.

In solid roofs, install using a roof plate assembly and, if required, and eggcrate grille in the ceiling below. A suitable sealing compound should be used between the glass/roof plate and the exterior seal.

DIMENSIONS:

Impeller dia. 150mm 190mm 230mm 300mm
A 140 147 166 201
216 254 295 381
C 21 21 21 21
D 95 108 121 146
267 330 394 508
Fixing hole dia. 184 222 260 337
Weight 3.2kg 3.9kg 5.5kg 8.5kg
---
Size A B C
6 300 mm 335 mm 475 mm
7 300 mm 335 mm 475 mm
9 450 mm 490 mm 630 mm
12 450 mm 490 mm 630 mm
Image of Standard Range Roof Model S7RF
Standard Range Roof Model S7RF
Classic Retro-Styled Ventilation A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard Range makes installation and routine cleaning easy
Please call 0344 856 0590 for further availability information.
Image of Standard Range Roof Model S6RF
Standard Range Roof Model S6RF
Classic Retro-Styled Ventilation A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard Range makes installation and routine cleaning easy.
Please call 0344 856 0590 for further availability information.
Image of Standard Range Roof Model S9RF
Standard Range Roof Model S9RF
Classic Retro-Styled Ventilation A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard Range makes installation and routine cleaning easy.
Please call 0344 856 0590 for further availability information.
Image of Standard Range Roof Model S12RF
Standard Range Roof Model S12RF
Classic Retro-Styled Ventilation A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard Range makes installation and routine cleaning easy.
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Controller
Ecotronic Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Please call 0344 856 0590 for further availability information.
Image of Ambient Response Humidity Sensor Lo-Carbon
Ambient Response Humidity Sensor Lo-Carbon
Designed specifically for the Lo-Carbon product range. The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Night time RH increment setback feature suppresses nuisance ripping when the humidity level gradually rises as the temperature falls. Features & Benefits: Ambient operating temp range +5°C to +40°C. Changeover relay switch. DEMKO Approved. Dimensions: 87 x 87 x 33mm (H x W x D). Operating range: 30%-90% RH. Pullcord override and neon indicator. Will fit single gang box for surface mounting. Downloads Catalogue Pages
Please call 0344 856 0590 for further availability information.
Image of Air Quality Sensor (Sentinel)
Air Quality Sensor (Sentinel)
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Humidity Sensor (Sentinel)
Ecotronic Humidity Sensor (Sentinel)
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
Please call 0344 856 0590 for further availability information.

Overview

Classic Retro-Styled Ventilation
A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard range makes installation and routine cleaning easy.

Featuring a low profile cowl, the unit is ready for fitting into horizontal, angled and vertical glass, fixing plates on roofs and in vertical windows or walls in exposed areas. With Vent-Axia roof plate assemblies, all four sizes can be fitted easily into flat roofs. Suitable for roof installation plus window and wall installation in exposed areas (eg: coastal positions).

Vent-Axia's spigot and ring method of fixing ensures easy installation and weather proof joint. We recommend the use of sealing compound under the upper part of the unit when fitted in roofs.

Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools.

Motor
Purpose designed enclosed motor. Suitable for running at any angle. Quiet running, continuous rated motor with sealed for life ball bearings.

Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.).

Supply voltage 220-240V/1/50Hz.

All Standard Range roof models are designed to fit directly into horizontal and sloping windows including wired cast, up to 10mm thick.

In solid roofs, install using a roof plate assembly and, if required, and eggcrate grille in the ceiling below. A suitable sealing compound should be used between the glass/roof plate and the exterior seal.

Technical

DIMENSIONS:

Impeller dia. 150mm 190mm 230mm 300mm
A 140 147 166 201
216 254 295 381
C 21 21 21 21
D 95 108 121 146
267 330 394 508
Fixing hole dia. 184 222 260 337
Weight 3.2kg 3.9kg 5.5kg 8.5kg
---
Size A B C
6 300 mm 335 mm 475 mm
7 300 mm 335 mm 475 mm
9 450 mm 490 mm 630 mm
12 450 mm 490 mm 630 mm

Models

Image of Standard Range Roof Model S7RF
Standard Range Roof Model S7RF
Classic Retro-Styled Ventilation A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard Range makes installation and routine cleaning easy
Please call 0344 856 0590 for further availability information.
Image of Standard Range Roof Model S6RF
Standard Range Roof Model S6RF
Classic Retro-Styled Ventilation A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard Range makes installation and routine cleaning easy.
Please call 0344 856 0590 for further availability information.
Image of Standard Range Roof Model S9RF
Standard Range Roof Model S9RF
Classic Retro-Styled Ventilation A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard Range makes installation and routine cleaning easy.
Please call 0344 856 0590 for further availability information.
Image of Standard Range Roof Model S12RF
Standard Range Roof Model S12RF
Classic Retro-Styled Ventilation A versatile and robust range of roof extract ventilating units designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard Range makes installation and routine cleaning easy.
Please call 0344 856 0590 for further availability information.

Accessories

Image of Ecotronic Controller
Ecotronic Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Please call 0344 856 0590 for further availability information.
Image of Ambient Response Humidity Sensor Lo-Carbon
Ambient Response Humidity Sensor Lo-Carbon
Designed specifically for the Lo-Carbon product range. The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Night time RH increment setback feature suppresses nuisance ripping when the humidity level gradually rises as the temperature falls. Features & Benefits: Ambient operating temp range +5°C to +40°C. Changeover relay switch. DEMKO Approved. Dimensions: 87 x 87 x 33mm (H x W x D). Operating range: 30%-90% RH. Pullcord override and neon indicator. Will fit single gang box for surface mounting. Downloads Catalogue Pages
Please call 0344 856 0590 for further availability information.
Image of Air Quality Sensor (Sentinel)
Air Quality Sensor (Sentinel)
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Please call 0344 856 0590 for further availability information.
Image of Ecotronic Humidity Sensor (Sentinel)
Ecotronic Humidity Sensor (Sentinel)
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
Please call 0344 856 0590 for further availability information.

Downloads