Sentinel Kinetic F

• Ultra quiet
• Lightweight for easier installation
• Horizontal duct option for space-saving
installations
• Integrated digital controller for simple
and accurate commissioning
• Plug and play controls; Humidistat,
Ventwise, Wireless Remote
• BMS connectivity
• LS inputs (Light Switch)
• Volt-free inputs
• Self diagnosis for simplified fault finding
• Adjustable delay On/delay Off timer

Easy Installation

The Sentinel Kinetic models can be mounted vertically
in a roof space or in an appropriate cupboard within
the dwelling. When mounted in an unheated area
the ducting and unit must be insulated in accordance
with the Domestic Ventilation Compliance Guide.
Ducting can be attached to the unit horizontally,
vertically or both.
Left (L) or right (R) hand installation. Left hand and
right hand units are available.

Spigot Options

The combination of spigot options allows installation
in confined locations. If vertical and horizontal
connection is required on the same outlet/inlet,
additional spigots can be supplied.
The condensate drain can be taken out through
the back, side or bottom of the unit. Using the
fittings supplied, the final condensate connection is
made outside the unit and can be completed after
installation.

Integral Humidity Sensor

The integral humidity sensor increases speed in
proportion to relative humidity levels, saving energy
and reducing noise. The sensor also reacts to small
but rapid increases in humidity, even if the normal
trigger threshold is not reached. This unique feature
ensures adequate ventilation, even for the smallest
wet room. The night time relative humidity setback
feature suppresses nuisance tripping as humidity
gradually increases with falling temperature.

 

Overview

Easy Installation

The Sentinel Kinetic models can be mounted vertically
in a roof space or in an appropriate cupboard within
the dwelling. When mounted in an unheated area
the ducting and unit must be insulated in accordance
with the Domestic Ventilation Compliance Guide.
Ducting can be attached to the unit horizontally,
vertically or both.
Left (L) or right (R) hand installation. Left hand and
right hand units are available.

Spigot Options

The combination of spigot options allows installation
in confined locations. If vertical and horizontal
connection is required on the same outlet/inlet,
additional spigots can be supplied.
The condensate drain can be taken out through
the back, side or bottom of the unit. Using the
fittings supplied, the final condensate connection is
made outside the unit and can be completed after
installation.

Integral Humidity Sensor

The integral humidity sensor increases speed in
proportion to relative humidity levels, saving energy
and reducing noise. The sensor also reacts to small
but rapid increases in humidity, even if the normal
trigger threshold is not reached. This unique feature
ensures adequate ventilation, even for the smallest
wet room. The night time relative humidity setback
feature suppresses nuisance tripping as humidity
gradually increases with falling temperature.

Technical

 