HR500EP/IP

Passive - no fans
Lightweight - easy installation
Compatible with 315, 250 and 200mm Ø ducting and accessories
Saves Heat - 70% heat recovery
External wall mounting
 

Select a product

The unit is a semi-remote heat exchange unit with 70% heat recovery, designed for mounting in internal walls (HR500IP) and external walls (HR500EP) for installations using ducted extraction and fresh air supply. The HR500 units provides air movement via two independent in-line duct fans to suit length and configuration of ducting systems. The unit is ideal for use with in-line centrifugal type fans and compatible accessories. Performance of HR500EP and HR500IP: Up to 244 l/s FID capacity (balanced airflow). Ideal for computer rooms, classrooms, offices and the health & leisure industries.

Fan options:

ACP
ACM
ACQ

 

DIMENSIONS:

Fitting Hole Size: 610mm × 381mm
Weight: 10kg

Image of HR500EP
HR500EP

The HR500EP unit is designed for mounting in an external wall. The unit has no fans fitted and is ideal for systems where centrifugal in-line fans are used to overcome increased external static pressure from long duct runs or multiple grille applications.The unit incorporates a polymer heat exchanger in a light weight plastic enclosure with two spigots for easy ducting connection.The unit maintains the separation of extracted air and fresh air supply whilst transferring up to 70% of the waste heat from extracted foul air.

Performance of HR500EP: Up to 244 l/s FID capacity (balanced airflow). Ideal for computer rooms, classrooms, offices and the health & leisure industries.

Installation
The HR500EP unit is designed for mounting in an external wall and should be fitted to provide a 3° slope to outside to provide condensate drainage.The unit has no fans fitted and is ideal for systems where centrifugal in-line fans are used to overcome increased external static pressure from long-duct runs or multiple-grille applications.

Fan Options

ACP
ACM
ACQ

Please call 0344 856 0590 for further availability information.
Image of HR500IP
HR500IP

The HR500IP unit is a semi-remote heat exchange unit with 70% heat recovery, designed for mounting in internal walls for installations using ducted extraction and fresh air supply. The HR500IP unit provides air movement via two independent in-line duct fans to suit length and configuration of ducting systems. The unit is ideal for use with with in-line centrifugal type fans and compatible accessories.

Performance of HR500IP: Up to 244 l/s FID capacity (balanced airflow). Ideal for schools, offices, pubs and clubs, etc.

Fan Options

ACP
ACM
ACQ

Installation
The unit should be set in an inner wall with the grille flange set flush with the inner surface (a steel lintel is provided for additional support of building fabric if required). Automatically produce a 3° slope of the unit away from the inner grille for drainage of any condensate which may form during operation. A 22mm drain is situated between inlet and exhaust spigots and should be connected to a suitable drain/soak away

Please call 0344 856 0590 for further availability information.

 

Raadpleeg de tab Downloads voor technische informatie

 

 

ESTIMATED RUNNING COSTS

Calculate estimated running costs for this product using the tool below.
For average costs, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations.


pence
(Your current electricity cost in pence per hour. This will be listed on your electric bill)
hours
(The average number of hours per day fan to run in Trickle mode)
hours
(The average number of hours per day fan to run in Boost mode)

Based on the inputted figures, estimated running costs would be:

Overview

The unit is a semi-remote heat exchange unit with 70% heat recovery, designed for mounting in internal walls (HR500IP) and external walls (HR500EP) for installations using ducted extraction and fresh air supply. The HR500 units provides air movement via two independent in-line duct fans to suit length and configuration of ducting systems. The unit is ideal for use with in-line centrifugal type fans and compatible accessories. Performance of HR500EP and HR500IP: Up to 244 l/s FID capacity (balanced airflow). Ideal for computer rooms, classrooms, offices and the health & leisure industries.

Fan options:

ACP
ACM
ACQ

 

Technical

DIMENSIONS:

Fitting Hole Size: 610mm × 381mm
Weight: 10kg

Models

Image of HR500EP
HR500EP

The HR500EP unit is designed for mounting in an external wall. The unit has no fans fitted and is ideal for systems where centrifugal in-line fans are used to overcome increased external static pressure from long duct runs or multiple grille applications.The unit incorporates a polymer heat exchanger in a light weight plastic enclosure with two spigots for easy ducting connection.The unit maintains the separation of extracted air and fresh air supply whilst transferring up to 70% of the waste heat from extracted foul air.

Performance of HR500EP: Up to 244 l/s FID capacity (balanced airflow). Ideal for computer rooms, classrooms, offices and the health & leisure industries.

Installation
The HR500EP unit is designed for mounting in an external wall and should be fitted to provide a 3° slope to outside to provide condensate drainage.The unit has no fans fitted and is ideal for systems where centrifugal in-line fans are used to overcome increased external static pressure from long-duct runs or multiple-grille applications.

Fan Options

ACP
ACM
ACQ

Please call 0344 856 0590 for further availability information.
Image of HR500IP
HR500IP

The HR500IP unit is a semi-remote heat exchange unit with 70% heat recovery, designed for mounting in internal walls for installations using ducted extraction and fresh air supply. The HR500IP unit provides air movement via two independent in-line duct fans to suit length and configuration of ducting systems. The unit is ideal for use with with in-line centrifugal type fans and compatible accessories.

Performance of HR500IP: Up to 244 l/s FID capacity (balanced airflow). Ideal for schools, offices, pubs and clubs, etc.

Fan Options

ACP
ACM
ACQ

Installation
The unit should be set in an inner wall with the grille flange set flush with the inner surface (a steel lintel is provided for additional support of building fabric if required). Automatically produce a 3° slope of the unit away from the inner grille for drainage of any condensate which may form during operation. A 22mm drain is situated between inlet and exhaust spigots and should be connected to a suitable drain/soak away

Please call 0344 856 0590 for further availability information.

Downloads