HR400

Controls condensation and odours
Up to 70% heat recovery
Balanced supply and extract air flows
Eliminates mould growth
Reduced redecorating cost
Added security benefits
Benefits to asthma and hay fever sufferers

This product range is now obsolete and no longer available from Vent-Axia. The information here is provided for reference only.

The HR400 is a wholehouse ventilation system comprising a fan assisted heat recovery unit.The HR400 is usually installed as a single unit, but multiple systems can be used for zoning or increased capacity. The unit offers an optional pollen filter for the fresh air supply, this option benefits asthma and hay fever sufferers.

Selectable performance levels: Up to 86 l/s, based on typical ducted systems. The HR400 can be used installed in many types of building - houses, flats, bungalow’s, offices and nursing homes,etc.

Installation
All components for wholehouse systems are fully compatible, resulting in a wide range of options for the system specification. All units are supplied with a comprehensive installation guide, providing step by step instructions for successful installation. In addition, a full backup service is available if required, with experienced engineers available to answer any queries you may have concerning your installation.

PERFORMANCE:

HR400 to be used with a VCON77 Transformer for maximum controllabilty

Motor Speed 1 2 3 4 5 6
Volume l/s (FID) 39 50 61 68 75 86

DIMENSIONS:

Weight: 19kg

Power Consumption
Speed 1 80V N/A
Speed 2 100V 71W
Speed 3 120V 87W
Speed 4 140V 101W
Speed 5 160V 115W
Speed 6 240V 179W

Overview

The HR400 is a wholehouse ventilation system comprising a fan assisted heat recovery unit.The HR400 is usually installed as a single unit, but multiple systems can be used for zoning or increased capacity. The unit offers an optional pollen filter for the fresh air supply, this option benefits asthma and hay fever sufferers.

Selectable performance levels: Up to 86 l/s, based on typical ducted systems. The HR400 can be used installed in many types of building - houses, flats, bungalow’s, offices and nursing homes,etc.

Installation
All components for wholehouse systems are fully compatible, resulting in a wide range of options for the system specification. All units are supplied with a comprehensive installation guide, providing step by step instructions for successful installation. In addition, a full backup service is available if required, with experienced engineers available to answer any queries you may have concerning your installation.

Technical

PERFORMANCE:

HR400 to be used with a VCON77 Transformer for maximum controllabilty

Motor Speed 1 2 3 4 5 6
Volume l/s (FID) 39 50 61 68 75 86

DIMENSIONS:

Weight: 19kg

Power Consumption
Speed 1 80V N/A
Speed 2 100V 71W
Speed 3 120V 87W
Speed 4 140V 101W
Speed 5 160V 115W
Speed 6 240V 179W